Lastly, the care instructions are crucial. While some heavy duvet inserts can withstand machine washing, others may require professional cleaning. Always follow the manufacturer's guidelines to ensure the longevity of your investment.
If the zinc coating is good, but in 3% nitric acid when the light, the coating has dark shadow, passivation occurs when the film is brown, may be caused by foreign metal impurities such as copper or lead in the galvanizing liquid. When problems occur in the process of galvanizing large coil galvanized wire, the temperature and current density are checked first, and then the content of zinc and sodium hydroxide in the plating solution is measured and adjusted through the analysis of the plating solution. Whether DPE content is low can be determined by hull cell test.
- 3. The structure of the dog cage should be reasonable
Hot wire plating adopts zinc-free slag to add hot molten zinc and galvanizing, which avoids the traditional heating process, radiates 1653 hot molten zinc on surface 4102 of zinc liquid surface, and reduces the high temperature oxidation of zinc liquid surface. At the same time, the heating body is in contact with the zinc liquid, and the heat is directly transferred to the zinc liquid. The utilization rate of heat energy can reach more than 90%, and the heat radiation on the zinc liquid surface is reduced.
Post time: 17-04-23There are a variety of arc, non-divergence Angle and non-divergence height ladder types installed to provide ideal treatment plans. It can be used together with the appearance and the common design of the trackless active shift door, forming a harmonious and intact whole.
Post time: 17-06-24Hot dip galvanizing, also known as hot dip galvanizing, is a method of obtaining a metal covering layer by immersing a steel member into a molten zinc solution. With the rapid development of high-voltage power transmission, transportation and communication, the protection requirements for steel parts are becoming higher and higher, and the demand for hot-dip galvanizing is also increasing. Usually the thickness of electrogalvanized layer is 5 ~ 15μm, and the large roll galvanized wire layer is generally more than 35μm, or even up to 200μm. Hot dip galvanized coating ability is good, dense coating, no organic inclusions.
The insulation layer of large rolls of galvanized wire and rigid thermal insulation products can be bound with double strands of galvanized iron wire, and the binding interval shall not exceed 400mm. The pipe or corresponding equipment with nominal diameter equal to or greater than 600mm shall stop reinforcement after binding, and the enclosed galvanized steel wire must be winched. The iron or wood rod should be tightened, but the tightening level should be moderate, not too tight or too loose, and not damage the wire. The consumption of wire and steel wire is generally used in drawing process and galvanized disposal.
Post time: 20-12-22The smaller the mesh of decorative hook mesh, the finer the demand wire, the larger the mesh, the thicker the demand wire. For example, the mesh aperture of 6.5cm requires an iron diameter of 3.5mm to 4mm. Then a fine welding will break, and then thick too heavy, workers can not bear.
Hot wire mesh in the building wall engineering mainly played the anti-crack effect, inside and outside the use of specifications are not the same. Hot dipped wire material choose low carbon wire, through automation welding precision machinery processing after forming, surface treatment by zinc immersion process, galvanized barbed wire surface smooth and tidy, uniform structure strong, the overall performance is good, even if the local cutting or under pressure will not loose phenomenon occurs, it is the iron mesh strong anticorrosion performance in one of the widely used net class.
- Ask the factory to provide the corresponding quality inspection report before packing. Cold drawing is a kind of material often used in our life, especially in the construction of buildings. Cold wire drawing is used more in building materials, cold wire drawing testing standards are also different. The strength of cold wire drawing is high, and it can be used in many aspects. Where plasticity is not required, only strength is required, such steel can be used.
After the corrosion of impregnated hexagonal wire mesh, the original characteristics will be lost, and the shape, color and mechanical properties will be changed, resulting in equipment damage, pipeline leakage, etc., specifically, it is easy to break and lose the original protection function. Usually, there are three kinds of metal corrosion: physical corrosion, chemical corrosion, electrochemical corrosion, corrosion in addition to the chemical properties and organizational structure of the metal itself, but also related to the surrounding medium, such as wet environment is easier to rust than dry environment, more impurities than impurities less easy corrosion, high temperature conditions than low temperature conditions easy corrosion. After understanding these, we can effectively prevent the corrosion of impregnated six-sided wire mesh, prolong the service life of the product.
- In addition to these reasons, we should pay attention to the tooling and process must be stable, and regular testing should be done to ensure the uniformity of galvanized layer.
Post time: 12-08-22Cold wire drawing is mainly used in the production of hardened low carbon steel wire, with a diameter of 8 mm steel bar to play a fixed role in the development of the construction industry has played a role in promoting the development of the construction industry, widely used. The bonding and anchorage performance between cold wire drawing and concrete is good. When used in components, the phenomenon of cracking in the anchorage area of components and damage caused by steel wire slip is fundamentally eliminated, and the bearing capacity and anti-cracking capacity of the end of components are improved.
Post time: 28-01-23
Post time: 16-11-22- (2) The construction is simple and does not need special technology;
In our daily life, we are certainly familiar with the construction of power grid. Choosing such special barbed rope can improve the safety factor of the entire power grid during construction.
- In the calculation process of 12*14 specifications of barbed rope, it can not be calculated according to the above calculation formula, because first of all, two specifications of raw materials are used, the thinner the wire diameter, the higher the processing cost. Generally speaking, a kilogram of 12*14 barbed rope can reach about 7.5 meters, and the ratio of warp wire to barbed rope cannot be calculated according to the traditional ratio of 7 to 3. The exact amount of stinging and use the warp need to increase after a series of professional measurement on the loss of raw materials and so on factors to calculate.
Post time: 05-05-23
Post time: 04-08-22
Post time: 06-07-22- (3) It has a strong ability to resist natural damage, corrosion resistance and adverse climate impact;